Search results for " diagnostics"
showing 10 items of 170 documents
XUV diagnostic to monitor H-like emission from B, C, N, and O for the W7-X stellarator
2019
The “C/O Monitor” system for the Wendelstein 7-X (W7-X) stellarator is a dedicated spectrometer with high throughput and high time resolution (order of 1 ms) for fast monitoring of content of low-Z impurities in the plasma. The observed spectral lines are fixed to Lyman-α lines of H-like atoms of carbon (3.4 nm), oxygen (1.9 nm), nitrogen (2.5 nm), and boron (4.9 nm). The quality of the wall condition will be monitored by the measurements of oxygen being released from the walls during the experiments. The strong presence of carbon is an indication for enhanced plasma-wall interaction or overload of plasma facing components. The presence of nitrogen (together with oxygen) may indicate a poss…
Correlations between density distributions, optical spectra, and ion species in a hydrogen plasma (invited)
2016
An experimental study of plasma distributions in a 2.45 GHz hydrogen discharge operated at 100 Hz repetition rate is presented. Ultrafast photography, time integrated visible light emission spectra, time resolved Balmer-alpha emission, time resolved Fulcher Band emission, ion species mass spectra, and time resolved ion species fraction measurements have been implemented as diagnostic tools in a broad range of plasma conditions. Results of plasma distributions and optical emissions correlated with H + , H + 2 , and H + 3 ion currents by using a Wien filter system with optical observation capability are reported. The magnetic field distribution and strength is found as the most critical facto…
Photoelectron Emission from Metal Surfaces Induced by Radiation Emitted by a 14 GHz Electron Cyclotron Resonance Ion Source
2015
Photoelectron emission measurements have been performed using a room-temperature 14 GHz ECR ion source. It is shown that the photoelectron emission from Al, Cu, and stainless steel (SAE 304) surfaces, which are common plasma chamber materials, is predominantly caused by radiation emitted from plasma with energies between 8 eV and 1 keV. Characteristic X-ray emission and bremsstrahlung from plasma have a negligible contribution to the photoelectron emission. It is estimated from the measured data that the maximum conceivable photoelectron flux from plasma chamber walls is on the order of 10% of the estimated total electron losses from the plasma. peerReviewed
Time resolved measurements of hydrogen ion energy distributions in a pulsed 2.45 GHz microwave plasma
2017
A plasma diagnostic study of the Ion Energy Distribution Functions (IEDFs) of H+, H+2H2+, and H+3H3+ ions in a 2.45 GHz hydrogen plasma reactor called TIPS is presented. The measurements are conducted by using a Plasma Ion Mass Spectrometer with an energy sector and a quadrupole detector from HIDEN Analytical Limited in order to select an ion species and to measure its energy distribution. The reactor is operated in the pulsed mode at 100 Hz with a duty cycle of 10% (1 ms pulse width). The IEDFs of H+, H+2H2+, and H+3H3+ are obtained each 5 μs with 1 μs time resolution throughout the entire pulse. The temporal evolution of the plasma potential and ion temperature of H+ is derived from the d…
Ion source research and development at University of Jyväskylä: Studies of different plasma processes and towards the higher beam intensities
2015
MonPS16; International audience; The long-term operation of high charge state electron cyclotron resonance ion sources fed withhigh microwave power has caused damage to the plasma chamber wall in several laboratories.Porosity, or a small hole, can be progressively created in the wall on a year time scale, which cancause a water leak from the cooling system into the plasma chamber vacuum. A burnout of theVENUS chamber is investigated. Information on the hole formation and on the necessary localhot electron power density is presented. Next, the hot electron flux to the wall is studied bymeans of simulations. First, the results of a simple model assuming that electrons are fullymagnetized and …
Estimating ion confinement times from beam current transients in conventional and charge breeder ECRIS
2019
International audience; Cumulative ion confinement times are probed by measuring decaying ion current transients in pulsed material injection mode. The method is applied in a charge breeder and conventional ECRIS yielding mutually corroborative results. The cumulative confinement time estimates vary from approximately 2 ms–60 ms with a clear dependence on the ion charge-to-mass ratio—higher charges having longer residence times. The long cumulative confinement times are proposed as a partial explanation to recently observed unexpectedly high ion temperatures. The results are relevant for rare ion beam (RIB) production as the confinement time and the lifetime of stable isotopes can be used f…
Controlled feeding experiments with diets of different abrasiveness reveal slow development of mesowear signal in goats ( Capra aegagrus hircus )
2018
ABSTRACT Dental mesowear is applied as a proxy to determine the general diet of mammalian herbivores based on tooth-cusp shape and occlusal relief. Low, blunt cusps are considered typical of grazers and high, sharp cusps typical of browsers. However, how internal or external abrasives impact mesowear, and the time frame the wear signature takes to develop, still need to be explored. Four different pelleted diets of increasing abrasiveness (lucerne, grass, grass and rice husks, and grass, rice husks and sand) were fed to four groups of a total of 28 adult goats in a controlled feeding experiment over a 6-month period. Tooth morphology was captured by medical CT scans at the beginning and end…
Raspberry breeding and biotisation for increasing plant stress tolerance and antioxidant activity
2008
International audience; Chemical inputs used in red fruit production can be detrimental to the environment and pesticides are not always efficient in controlling plant diseases. In addition, it is suspected that conventional agricultural practices have a negative impact on antioxidant activities in red fruits. Therefore new cultural approaches are required in order to produce red fruits of high quality. This involves an integrated programme of plant breeding and development of sustainable agricultural practices. Antioxidant activity was compared in leaves and berries of six raspberry cultivars for the selection of varieties for a breeding programme. This showed that cultivars that had the h…
A review of diagnostics and prognostics of low-speed machinery towards wind turbine farm-level health management
2016
Abstract Large wind farms are gaining prominence due to increasing dependence on renewable energy. In order to operate these wind farms reliably and efficiently, advanced maintenance strategies such as condition based maintenance are necessary. However, wind turbines pose unique challenges in terms of irregular load patterns, intermittent operation and harsh weather conditions, which have deterring effects on life of rotating machinery. This paper reviews the state-of-the-art in the area of diagnostics and prognostics pertaining to two critical failure prone components of wind turbines, namely, low-speed bearings and planetary gearboxes. The survey evaluates those methods that are applicabl…
Transferability of PCR-based diagnostic protocols: An international collaborative case study assessing protocols targeting the quarantine pine pathog…
2019
Producción Científica